Features
Principle | Colorimetric & Turbidimetric |
Input | 5-inch touch screen and keypad |
Assay Method |
|
Optics |
|
Light Source |
|
Temperature Control |
|
Flowcell |
|
Storage |
|
Printer | Built-in Internal thermal printer |
Interface |
|
Power & Environmental Requirements |
|
Dimension | 355mm(H) x 330mm(W) x 175mm(D) |
Net Weight | 5.6 Kg |
Features
Sample / Reagent System | |
---|---|
Sample/Reagent tray | 40 positions for sample and reagent respectively in refrigerated compartment (4 – 12OC) |
Sample volume | 2 - 50µl, step by 0.1µl |
Reagent volume |
|
Sample/Reagent probe | Liquid level detection, automatic probe depth adjustment and collision protection |
Sample tube | Compatible with blood collection tube, minimal tube, sample cup etc. |
Reagent bottle | Compatible with various sizes reagent bottles |
Reaction System | |
Cuvette | Special ultraviolet transmitting plastic cuvettes and optical length of 5mm |
Reaction volume | 150µl – 500 µl |
Heating | Fully sealed constant temperature, heated by solid substance, fast and steady |
Reaction Temperature | 37±0.1OC |
Mixing system | Independent mixing probe |
Reaction cuvette | Disposable |
Optical System | |
Light source | 20W/12V halogen lamp, lifetime 2000 hours |
Photometric method | Airtight Static Matrix Optical System (ASMOS), full-sealed, maintenance free |
Wavelength | 8 wavelengths: 340, 405, 450, 510, 546, 578, 630 and 670nm, support single/dual wavelength |
Absorbance range | 0 – 4.00 Abs |
Calibration & Control | |
Calibration mode | Linear, Logit-log 4P, Logit-log 5P, Spline, Exponential, Polynomial |
Control rule | Westgard multi-rule, Cumulative sum check, Twin plot |
Operation Unit | |
Operation system | Windows based operating system |
Interface | RS-232 |
Others | |
Power supply | AC 100V – 240V, 50Hz/60Hz |
Power | 300W |
Dimension | 855mm x 650.5mm x579 mm |
Net Weight | 80 kg |
Features
Sample / Reagent System | |
---|---|
Sample/Reagent tray | 40 positions for sample and reagent respectively in refrigerated compartment (4 – 12OC) |
Sample volume | 2 - 50µl, step by 0.1µl |
Reagent volume |
|
Sample/Reagent probe | Liquid level detection, automatic probe depth adjustment & collision protection |
Sample tube | Compatible with blood collection tube, minimal tube, sample cup etc. |
Reagent bottle | Compatible with various sizes reagent bottles |
Reaction System | |
Cuvette | Special ultraviolet transmitting plastic cuvettes and optical length of 5mm |
Reaction volume | 150µl – 500 µl |
Heating | Fully sealed constant temperature, heated by solid substance, fast and steady |
Reaction Temperature | 37±0.1OC |
Mixing system | Independent mixing probe |
Cleaning system | On-board laundry with 6-step washing function |
Optical System | |
Light source | 20W/12V halogen lamp, lifetime 2000 hours |
Photometric method | Rear spectrophotometry by filter technology, fully sealed, free from mildew. |
Wavelength | 8 wavelengths: 340, 405, 450, 510, 546, 578, 630 and 670nm, support single/dual wavelength |
Absorbance range | 0 – 4.00 Abs |
Calibration & Control | |
Calibration mode | Linear, Logit-log 4P, Logit-log 5P, Spline, Exponential, Polynomial |
Control rule | Westgard multi-rule, Cumulative sum check, Twin plot |
Operation Unit | |
Operation system | Windows based operating system |
Interface | RS-232 |
Others | |
Power supply | AC 100V – 240V, 50Hz/60Hz |
Power | 350VA |
Dimension | 855mm x 640mm x560mm |
Net Weight | 100 kg |
Features
Overall performance | |
---|---|
Equipment type | Fully automatic, discrete, STAT priority |
Analysis rate | Colorimetry speed 180 T/H (single/double reagent) |
Test principle | Colorimetry, turbidimetry |
Analysis Method | End-point, Kinetic, Fixed time, etc. |
Sample Reagent Unit | |
Sample reagent positions | 40 standard can up to 80 |
Sample cuvettes specification | Standard cup, Original blood tube, multi-specification tubes available |
Sample/Reagent probe | 1, with the function of liquid level detection and collision protection |
Sample/Reagent Probe carrying rate | Automatic warm water cleaning |
Reaction Unit | |
Reaction Cuvette | 56 positions optical plastic cup |
Total volume of reaction liquid | 100µl – 360µl |
Reaction Temperature | 37oC |
Reaction disk constant temperature | Air bath |
Mixer | 1, after joining reagent, blending immediately |
Reaction cuvette cleaning | 8 stops 12 steps by warm water rinsing |
Optical System | |
Light source | 20W/12V halogen lamp |
Monochromator | Grating Photometry |
Photoelectron road | After spectrophotometry |
Wavelengths | 340nm-800nm |
Detector | Photodiode LED array |
Calibration & QC | |
Calibration Method | 1-point linear method, 2-point linear method, multipoint linear & non-linear method |
Calibration tracking | Automatic description calibration k-value trends |
QC method | Real-time QC, daily QC and monthly QC |
Out of control processing | Alarm for out of control sample |
Operating System | |
PC operating system | Windows 7 or Windows 10 |
Analysis control software | Graphical operating software English version |
Report printing | Report formats support the user-defined mode, QC and state information etc. |
System connection | TCP/IP network connection, standard RJ-45 |
Others | |
Volume | 744mm x 703mm x 530mm |
Weight | 100kg |
Power supply | Voltage AC 100V-240V, 50/60Hz, power 600VA |
Features
Fully automated bench-top Random Access Clinical Chemistry analyser
Throughput
Sample Reagent Unit | |
---|---|
Sample reagent positions | The reagent and sample share one disk, totally 67 positions. Continuously cooling at all positions to keep 5~150C within 24 hrs. |
Sample volume | 3 - 35 μL with increments of 0.1 μL |
Reagent volume | R1: 10μl~350μl, R2: 10μl~200μl, 1μl stepping |
Sampling technology | Liquid level detection and collision protection |
Sample tube | Standard cups, original blood tube, multi-specification tubes available |
Sample reagent probe | 1, with function of liquid level detection and collision protection |
Sample reagent probe carrying rate | automatic warm water cleaning. Carrying rate <1.0% |
Automatic sample dilution | 2 ~ 115 times |
Reaction Unit | |
Reaction Cuvette | 120 positions optical plastic cup, optical diameter is 6mm |
Reaction volume | 150 μL ~ 550 μL |
Reaction disk constant temperature | Circulating water |
Reaction temp. | 37±0.1OC |
Mixing needle | 1, after joining reagent, blending immediately |
Cuvette cleaning system | 8 stops 12 steps by warm water rinsing |
Optical System | |
Light source | 20W/12V halogen lamp with lifetime of more than 2000 hours |
Photometric method | Grating Photometry |
Wavelength | 13 wavelengths 340nm, 380nm, 405nm, 450nm, 480nm, 505nm, 546nm, 570nm, 600nm, 660nm, 700nm, 750nm or 800 nm |
Detector | Photodiode LED array |
Absorbance range | 0~3.3Abs |
Calibration & Control | |
Calibration Method | 1 point linear method, 2 point linear method, multipoint linear method, non-linear method |
Calibration tracking | Automatic description calibration k-value trends |
QC method | real-time QC, days QC and day QC |
Operation Unit | |
Operation system | Windows XP |
Analysis control software | English version graphical operating software |
Report printing | Report formats support the user-defined mode, QC and state information etc. |
Interface | TCP/IP network connection, standard RS-232C |
Working Conditions | |
Power supply | Voltage AC 220V+22V, 50/60Hz |
Power | 650VA |
Dimension | 998mm X 752mm X 517 mm |
Net Weight | 120 Kg |
Features
Fully automated Random Access Clinical Chemistry analyser
Throughput
Sample Unit | |
---|---|
Sample tray/positions | 115 position(basic sample :50, calibrators:34, emergency sample 20, QC product: 8, detergent:3). Continuously cooling at calibration and QC positions to keep 5 - 150C within 24 hrs. |
Sample volume | 2 - 35 μL with increments of 0.1 μL |
Sampling technology | Liquid level detection and collision protection |
Sample tube | Standard cups, original blood tube, multi-specification tubes available |
Sample probe carrying rate | automatic warm water cleaning. Carrying rate <1.0% |
Automatic sample dilution | 3 ~ 170 times |
Reagent Unit | |
Reagent tray/positions | Single reagent disk, maximum 67 positions available, continuous 5~150C cooling within 24 hrs” |
Reagent volume | 20μl ~ 350μl, 1μl stepping |
Reagent probe | 1, with the function of liquid level detection and collision detection |
Reagent probe carrying rate | automatic warm water cleaning. Carrying rate <1.0% |
Reagent bottle | 70 ml, 20 ml or 100 ml standard reagent kit |
Reaction Unit | |
Reaction Cuvette | 120 positions optical plastic cup, optical diameter is 6mm |
Reaction volume | 150 μL ~ 450 μL |
Reaction disk constant temperature | Circulating water |
Reaction temp. | 37±0.1oC |
Mixing needle | 1, after joining reagent, blending immediately |
Cuvette cleaning system | - |
Optical System | |
Light source | 20W/12V halogen lamp with lifetime of more than 2000 hours |
Photometric method | Grating Photometry |
Wavelength | 13 wavelengths 340nm, 380nm, 405nm, 450nm, 480nm, 505nm, 546nm, 570nm, 600nm, 660nm, 700nm, 750nm or 800 nm |
Detector | Photodiode LED array |
Absorbance range | 0~3.3Abs |
Calibration & Control | |
Calibration Method | 1 point linear method, 2 point linear method, multipoint linear method, non-linear method |
Calibration tracking | Automatic description calibration k-value trends |
QC method | real-time QC, days QC and day QC |
Operation Unit | |
Operation system | Windows XP |
Analysis control software | English version graphical operating software |
Report printing | Report formats support the user-defined mode, QC and state information etc. |
Interface | TCP/IP network connection, standard RS-232C |
Working Conditions | |
Power supply | Voltage AC 220V+22V, 50/60HzVoltage AC 220V+22V, 50/60Hz |
Power | 1.5KVA |
Dimension | 1060mm X 790mm X 1150 mm |
Net Weight | 230 Kg |
Features
Fully automated Random Access Clinical Chemistry analyser
Throughput
Sample Unit | |
---|---|
Sample tray/positions | 115 position(basic sample : 50, calibrators:34, emergency sample 20,QC product: 8, detergent:3. Continuously cooling at calibration and QC positions to keep 5 - 150C within 24 hrs. |
Sample volume | 2 - 35 μL with increments of 0.1 μL |
Sampling technology | Liquid level detection, clot detection and collision protection |
Sample tube | Standard cups, original blood tube, multi-specification tubes available |
Sample probe carrying rate | automatic warm water cleaning. Carrying rate <1.0% |
Automatic sample dilution | 3 ~ 170 times |
Reagent Unit | |
Reagent tray/positions | Double reagent disk, 45x2, continuous 5 - 150C within 24 hrs. |
Reagent volume | R1: 20μL ~ 350μL, R2: 20μL ~ 350μL, R3: 20μL ~ 350μL, R4: 20μL ~ 350μL, |
Reagent probe | 2, with the function of liquid level detection and collision detection |
Reagent probe carrying rate | automatic warm water cleaning. Carrying rate <1.0% |
Reagent bottle | 70 ml, 20 ml |
Reaction Unit | |
Reaction Cuvette | 120 positions optical plastic cup, optical diameter is 6mm |
Reaction volume | 150 μL ~ 450 μL |
Reaction disk constant temperature | Circulating water |
Reaction temp. | 37±0.1o C |
Mixing needle | 2, after joining reagent, blending immediately |
Cuvette cleaning system | 7 stops 11 steps by warm water rinsing |
Optical System | |
Light source | Linear, Logit-log 4P, Logit-log 5P, Spline, Exponential, Polynomial |
Photometric method | Grating Photometry |
Wavelength | 13 wavelengths 340nm, 380nm, 405nm, 450nm, 480nm, 505nm, 546nm, 570nm, 600nm, 660nm, 700nm, 750nm or 800 nm |
Detector | Photodiode LED array |
Absorbance range | 0~3.3Abs |
Calibration & Control | |
Calibration Method | 1 point linear method, 2 point linear method, multipoint linear method, non-linear method |
Calibration tracking | Automatic description calibration k-value trends |
QC method | real-time QC, days QC and day QC |
Operation Unit | |
Operation system | Windows XP |
Analysis control software | English version graphical operating software |
Report printing | Report formats support the user-defined mode, QC and state information etc. |
Interface | TCP/IP network connection, standard RS-232C |
Working Conditions | |
Power supply | Voltage AC 220V+22V, 50/60HzVoltage AC 220V+22V, 50/60Hz |
Power | 2KVA |
Dimension | 1060mm X 790mm X 1150 mm |
Net Weight | 300 Kg |
Features
Fully automated Random Access Clinical Chemistry analyser
Throughput
Sample Unit | |
---|---|
Sample positions | 140 sample positions |
Sample volume | 1.5 - 35 μL with increments of 0.1 μL |
Sampling technology | Liquid level detection, liquid level tracing, clot detection and collision protection |
Sample tube | Standard cups, original blood tube, multi-specification tubes available |
Reagent Unit | |
Reagent tray/positions | 2 compartment, 132 reagent positions totally, with continuous refrigeration; supporting 4 kinds of reagent test functions |
Reagent volume | 15μL ~ 350μL |
Reagent probe | 2, with the function of liquid level detection, liquid level tracing and clot detection |
Reaction Unit | |
Reaction Cuvette | 160 new type reaction cuvettes |
Reaction volume | 120 μL ~ 450 μL |
Reaction temp. | 37±0.1o C |
Mixing needle | 2 independent mixers ensure sufficient reaction |
Optical System | |
Light source | 20W/12V halogen lamp with lifetime of more than 2000 hours |
Wavelength | 13 wavelengths 340nm, 380nm, 405nm, 450nm, 480nm, 505nm, 546nm, 570nm, 600nm, 660nm, 700nm, 750nm or 800 nm |
Calibration & Control | |
Calibration Method | 1 point linear method, 2 point linear method, multipoint linear method, non-linear method |
Calibration tracking | Automatic description calibration k-value trends |
QC method | real-time QC, days QC and day QC |
Features
Fully automated bench-top Random Access Clinical Chemistry analyser
Analysis Mode
Sample Reagent Unit | |
---|---|
Sample reagent positions | 78 positions in sample tray (62 routine and stat samples, 16 calibrators and controls), 48 cooled positions reagent corousel |
Sample volume | 1.8 - 100 μL |
Reagent volume | R1: 0.8μl~300μl, R2: 0.8μl~300μl |
Sample tube | Primary tube with barcode option, pediatric micro-sample cups |
Sample reagent probe | 1, Preheated and capacitive level sensor |
Sample Predilution | Yes |
Bottle Size | 50ml + 20ml, system packs available |
Reaction Unit | |
Reaction Cuvette | 32 positions reaction tray, optical glass cuvettes |
Reaction volume | 180 μL ~ 400 μL |
Reaction disk constant temperature | Peltier system |
Reaction temp. | Off/30/32/370C (+ 0.20C) |
Cuvette washing station | Yes |
Optical System | |
Light source | 35W/12V halogen lamp with lifetime of more than 2000 hours |
Photometric method | Solid state |
Wavelength | 340nm, 380nm, 405nm, 436nm, 480nm, 510nm, 546nm, 578nm, 630nm, 700nm |
Calibration & Control | |
Calibration Method | Semi-log, line for two points, minimum squares, multipoint (upto 6 calibrators) , polynomial, cubic spline, log-logit4, log-logit5 |
QC method | Westgard graph, Youden graph, L-J plot, Trender graph, Histogram |
Operation Unit | |
Operation system | Windows 2000, Windows XP, Windows Vista or Windows 7 |
Interface | USB 2.0 |
Working Conditions | |
Power supply | 110/230 VAC ; 50/60 Hz ; 300 watt |
Dimension | 51cm X 78cm X 58cm |
Net Weight | 120 Kg |
Features
Fully automated bench-top Random Access Clinical Chemistry analyser
Throughput
Sample Reagent Unit | |
---|---|
Sample reagent positions | 80 positions cooled for reagents, 100 positions for samples, calibrator and control trays 26 positions cooled |
Sample volume | 1.5 - 100μL |
Sampling technology | Liquid level detection, clot detection and collision protection |
Sample tube | Standard cups, original blood tube, multi-specification tubes available |
Sample reagent probe | 3, one sample arm and 2 reagent armswith function of liquid level detection and collision protection |
Sample pre-dilution | Yes |
Reagent bottles | System packs available |
Reaction Unit | |
Reaction Cuvette | 84 position optical glass cuvettes, heated |
Reaction volume | 180 μL ~ 400 μL |
Reaction disk constant temperature | Peltier controlled |
Reaction temp. | Off/30/32/370C (+ 0.20C) |
Mixing needle | 1, after joining reagent, blending immediately |
Cuvette washing station | Yes |
Optical System | |
Light source | Tungsten halogen lamp with dichroic reflector with lamp life more than 2000 hrs |
Photometric method | Solid state |
Wavelength | 340nm, 380nm, 405nm, 436nm, 480nm, 510nm, 546nm, 578nm, 600nm, 660nm, 700nm, 740nm & 800 nm |
Absorbance range | 0~3.0Abs |
Calibration & Control | |
Calibration Method | Factor, linear, with curve, multipoints, cubic spline, log-logit4, log-logit5, semi-log, polynomial, best fit |
Calibrator Predilution | Yes |
Operation Unit | |
Operation system | Windows XP |
Interface | USB port, RS232, port, LAN port |
Working Conditions | |
Power supply | 100/240 VAC; 50/60 Hz; 400 watt |
U.P.S | 1500 watt |
Dimension | 1150mm X 1150mm X 720mm (H x W x D) |
Net Weight | 162 Kg |
Gross Weight | 237 Kg |